Sensor Matrix

Physical Specifications

Parameter Specification
Configuration Ruggedised cable with thermistor sensor units
Enclosure Material Ruggedised, sealed cable assembly
Operating Temperature -30°C to +100°C
Environment Rating Underground hardrock mining rated

Temperature Sensing

Parameter Specification
Sensor Type NTC thermistor
Accuracy ±0.5°C across operating range
Resolution 0.1°C
Sampling Interval Configurable: 5 to 15 minutes

Three-Line Design

Parameter Specification
Configuration Three independent sensor lines per barricade
Coverage Full barricade wall face from base to crown
Detection Thermal gradient detection across barricade surface

Connectivity & Power Box

Physical Specifications

Parameter Specification
Enclosure Ruggedised, sealed enclosure
Environment Rating Underground hardrock mining rated

Communication

Parameter Specification
Technology Wireless RF transmission
Transmission Interval Configurable: 5 to 15 minutes
Security Encrypted data transmission

Power

Parameter Specification
Battery Type Long-life primary cell
Runtime 7+ days continuous operation
External Connections None required; fully self-contained

Edge Gateway Device

Physical Specifications

Parameter Specification
Operating Temperature -30°C to +70°C
Storage Temperature -40°C to +85°C
Humidity 10-95% non-condensing

Wireless Receiver

Parameter Specification
Concurrent Sensors Supports multiple concurrent sensor matrices

Backhaul Communication

Parameter Specification
Wi-Fi 2.4 GHz
Protocols MQTT (primary), HTTP/HTTPS, WebSocket
Security TLS 1.3, VPN support

Power

Parameter Specification
Input Connection USB-C to USB-C cable, 100W rated
Power Consumption Typical usage based on processor specifications

Algorithm Specifications

Parameter Specification
Standard ASTM C1074 compliant
Calculation Method Nurse-Saul equivalent age method
Maturity Index Temperature-time factor (°C-hours)
Strength Correlation R² ≥ 0.95 (95-98% typical)